Abstract
Geotechnical study of the Mikinduri area
was conducted with the aim to establish the causes of landslides and ground
subsidence during the heavy rainfall. Sounding curves, travel time curves, 2D
geoelectric sections, and 2D seismic models revealed 3-5 lithologic units to a
depth of 30-250m. The study established thick loose alluvium deposits mixed
with clay to a depth of 0.3-15m on an impermeable sub-basement as the possible
major trigger of the landslides witnessed during rainy seasons. The thick
alluvium deposits are due to erosion. They have been transferred by the
location of the Mikinduri area, which lies in the lower regions of the Nyambene
domes. Geologically, the domes were formed during Mount Kenya volcanic series
and parasitic activities between the early Miocene and late Pleistocene eras.
Resistivity modeling revealed deep geologic structures, including possible
intrusions extending from 50m deep and faulted regions to a depth of 60-150m in
the central and northeast area of study. The faulted area is highly saturated,
as revealed by the low resistivity values. The delineated top black cotton
soils and alluvium deposit are 40-50% clay and have poor foundation bearing
capabilities. In contrast, compacted gravel, silt, and compact basaltic rock
basement have good foundation capabilities.
Keywords: Geotechnical, characterization,
subsurface, seismic, electrical resistivity, foundation, geoelectric layer,
Mikinduri Meru, Kenya.